Communication PVC Conduit Sweep Bend Medium-Duty

Features & Benefits:

  • High-Quality Material: Made from durable medium-duty solid wall PVC.
  • Smooth Direction Changes: Gentle curves protect cables.
  • Easy, Simple Installation: Lightweight and cost-effective.
  • Standard and Custom Bends: Standard bends stocked. Custom bends available.

Description

Communication PVC Conduit Sweep Bend Medium-Duty

Seamless Direction Changes for Your Communication Installations

Convic Australia proudly supplies the Communication PVC Conduit Sweep Bend Medium-Duty, also known as PVC conduit bends or PVC sweep elbows. This ideal solution achieves smooth, directional changes in your communication conduit systems. Designed to offer flexibility and durability, these sweep bends ensure a seamless and reliable installation process for various applications.

 

Key Features and Benefits

  • High-Quality Material: Crafted from medium-duty solid wall PVC, our sweep bends, also referred to as PVC conduit sweep fittings, offer long-lasting performance and exceptional resistance to harsh environmental conditions.
  • Smooth Direction Changes: The gentle, sweeping curves allow for easy directional adjustments without compromising the integrity of your conduit system.
  • Easy Installation: Lightweight and easy to handle, these bends, sometimes known as communication conduit sweeps, simplify the installation process, reducing time and labor costs.
  • Versatile Angles: Available in standard angles such as 11°, 22°, 45°, and 90°, providing flexibility for various installation requirements.

 

Material & Colour

We supply bends crafted from robust PVC, ensuring they stand up to various environmental conditions. The white color is specifically used in communication tasks to enhance visibility and safety during installations and maintenance. This color coding helps in distinguishing communication conduits from those carrying hazardous materials, which are color-coded differently as per Australian standards​. Communication Conduit Bends are supplied using conduit in compliance with AS/NZS 2053:2:2001.

Differentiating Austel and Telstra/NBN Sizes

In communication applications, it is crucial to understand the specific size distinctions for proper installation:

  • 20mm and 50mm Sizes: The Austel standard measures these sizes from the outside diameter, while the Telstra/NBN standard, also used in rail projects, measures from the inside diameter. This difference is vital for ensuring compatibility with service requirements.
  • 100mm Size: This size is standardized and identical across both Austel and Telstra/NBN specifications, simplifying the installation process for this dimension.

Understanding these distinctions is essential to ensure your installations meet the required specifications and perform optimally. Always verify the required standard before proceeding with the installation to avoid compatibility issues.

 

Custom Capabilities

At Convic Australia, we understand that every project is unique. That’s why we offer custom fabrication for our sweep bends, adjusting to specific degrees and radii with quick turnaround times. Our versatility ensures you get the exact bend needed for your specific installation requirements.

 

Applications

Our Communication PVC Conduit Sweep Bends are perfect for:

  • Communication installations in residential, commercial, and industrial settings
  • Projects requiring smooth directional changes in conduit runs
  • Underground installations where durability is critical

 

Grasping the Utility of the Sweep Bend

The Communication PVC Conduit Sweep Bend, often called a conduit sweep or sweep bend, specifically alters the direction of communication conduits. While standard PVC bends might offer sharp angles, this sweeping bend provides a gentler curve, easing the transition for communication cables and reducing stress. This design minimizes the risk of cable damage, optimizing the system’s performance.

 

Why Choose Convic Australia?

Convic Australia provides high-quality, reliable products that meet your specific needs. Our Communication PVC Conduit Sweep Bend Medium-Duty exemplifies this dedication.

Contact us today to learn more about our range of Communication PVC Conduit Sweep Bends and other communication solutions. Let Convic Australia help you achieve seamless and efficient communication installations with our high-quality products.

Dimensions

Bends Measurements. DM (Diameter Measurement), Radius, Collar to Collar and overall arc length of bend.

20mm OD
Product Code Nominal Diameter Degree (°) Radius (r) Outside Diameter (OD) Dm Min Dm Max Collar to Collar
COMB2011150 20 11.25 150 20 20.1 20.4 29
COMB2022150 20 22.5 150 20 20.1  20.4 59
COMB2045150 20 45 150 20 20.1  20.4 115
COMB2090150 20 90 150 20 20.1  20.4 212

 

20mm ID
Product Code Nominal Diameter Degree (°) Radius (r) Outside Diameter (OD) Dm Min Dm Max Collar to Collar
TELB2011300 20 11.25 305 20 20.1 20.4 59
TELB2022300 20 22.5 305 20 20.1 20.4 117
TELB2045300 20 45 305 20 20.1 20.4 230
TELB2090300 20 90 305 20 20.1 20.4 424

 

32mm
Product Code Nominal Diameter Degree (°) Radius (r) Outside Diameter (OD) Dm Min Dm Max Collar to Collar
COMB3211150 32 11.25 150 32 32.1 32.4 29
COMB3222150 32 22.5 150 32 32.1 32.4 59
COMB3245150 32 45 150 32 32.1 32.4 115
COMB3290150 32 90 150 32 32.1 32.4 212

 

50mm OD
Product Code Nominal Diameter Degree (°) Radius (r) Outside Diameter (OD) Dm Min Dm Max Collar to Collar
COMB5011300 50 11.25 300 50 50.1 50.4 59
COMB5022300 50 22.5 300 50 50.1 50.4 117
COMB5045300 50 45 300 50 50.1 50.4 230
COMB5090300 50 90 300 50 50.1 50.4 424
COMB5011600 50 11.25 600 50 50.1 50.4 118
COMB5022600 50 22.5 600 50 50.1 50.4 234
COMB5045600 50 45 600 50 50.1 50.4 459
COMB5090600 50 90 600 50 50.1 50.4 849

 

50mm ID
Product Code Nominal Diameter Degree (°) Radius (r) Outside Diameter (OD) Dm Min Dm Max Collar to Collar
TELB5011300 50 11.25 305 50 50.1 50.4 59
TELB5022300 50 22.5 305 50 50.1 50.4 117
TELB5045300 50 45 305 50 50.1 50.4 230
TELB5090300 50 90 305 50 50.1 50.4 424
TELB5011600 50 11.25 305 50 50.1 50.4 118
TELB5022600 50 22.5 305 50 50.1 50.4 234
TELB5045600 50 45 305 50 50.1 50.4 459
TELB5090600 50 90 305 50 50.1 50.4 849

 

80mm
Product Code Nominal Diameter Degree (°) Radius (r) Outside Diameter (OD) Dm Min Dm Max Collar to Collar
COMB8011400 80 11.25 400 89.2 89.5 89.2 79
COMB8022400 80 22.5 400 89.2 89.5 89.2 156
COMB8045400 80 45 400 89.2 89.5 89.2 307
COMB8090400 80 90 400 89.2 89.5 89.2 565
COMB8011600 80 11.25 600 89.2 89.5 89.2 118
COMB8022600 80 22.5 600 89.2 89.5 89.2 234
COMB8045600 80 45 600 89.2 89.5 89.2 460
COMB8090600 80 90 600 89.2 89.5 89.2 848

 

100mm
Product Code Nominal Diameter Degree (°) Radius (r) Outside Diameter (OD) Dm Min Dm Max Collar to Collar
COMB10011450 100 11.25 450 114 114.8 115.1 88
COMB10022450 100 22.5 450 114 114.8 115.1 176
COMB10045450 100 45 450 114 114.8 115.1 344
COMB10090450 100 90 450 114 114.8 115.1 637
COMB10011600 100 11.25 600 114 114.8 115.1 118
COMB10022600 100 22.5 600 114 114.8 115.1 234
COMB10045600 100 45 600 114 114.8 115.1 459
COMB10090600 100 90 600 114 114.8 115.1 849
COMB100112000 100 11.25 2000 114 114.8 115.1 392
COMB100222000 100 22.5 2000 114 114.8 115.1 781
COMB100452000 100 45 2000 114 114.8 115.1 1531
COMB100902000 100 90 2000 114 114.8 115.1 2829

 

 

Notes:

  • All drawings, dimensions, weights, and volumes are approximate. Actual product dimensions may vary. If critical, please contact us to verify before use.
  • Dimensions are in mm
  • Nominal size refers to the outside diameter for 20-63mm, whereas greater than 80mm refers to internal dimensions.
  • M&F bends are generally used in one direction sweep bends or multi-part bends.

Standards

Electrical Conduit Bends are supplied using conduit in compliance with AS/NZS 2053:2:2001. They also align with the technical specifications set by Energy Queensland, Ausgrid, Essential Energy, Endeavour Energy, Main Roads, Jemena, Ausnet, and Powercor.